82 / 197 page ![]() Application information L99DZ100G, L99DZ100GP 82/197 DS11546 Rev 5 4.6.1 Change watchdog timing The watchdog trigger time is configured by setting WD_TIME_x (CR 2). Writing to these bits is possible only using the first SPI command after setting WD_CONFIG_EN = 1 (Config Reg). The WD_CONFIG_EN bit is reset to 0 automatically with the next SPI command. 4.7 Fail-safe mode 4.7.1 Temporary failures The devices enter Fail-safe mode in case of: Watchdog failure V1 turn on failure – V1 short (V1 < V1fail for t > tV1short) V1 failure (V1 < VRTxfalling for t > tV1FS) Thermal Shutdown TSD2 The Fail Safe functionality is also available in V1_Standby mode. During V1_Standby mode the Fail Safe mode is entered in the following cases: V1 failure (V1 < VRTxfalling for t > tV1FS) Watchdog failure (if watchdog still running due to IV1 > Icmp_fal) Thermal Shutdown TSD2 In Fail Safe mode the devices return to a fail safe state. The Fail Safe condition is indicated to the system in the Global Status Byte. The conditions during Fail Safe mode are: All outputs beside LS1_FSO and LS2_FSO are turned off All Control Registers are set to fail safe default values except: – SWEN (CR1<bit 7>): selective Wake-up enable – Partial Networking Configuration: CR23-CR29 Write operations to Control Registers are blocked until the Fail Safe condition is cleared. The following bits are not WRITE protected: – TRIG (CR1<bit 0>, Config Register <bit 0>): watchdog trigger bit – V2_x (CR1<bit 4:5>): Voltage Regulator V2 control – CAN_GO_TRX_RDY (CR1<bit 8>): activation of CAN transceiver – CR2 (bit <8:23>): Timer1 and Timer2 settings – OUT_HS_x (CR5 <bit 0:3>): OUT_HS configuration – OUT15_x (CR6<bit 0:3>): OUT15 configuration – PWMx_freq_y (CR12): PWM frequency configuration – PWMx_DC_y (CR13 – CR17): PWM duty cycle configuration LIN and HS CAN transmitter and SPI remain on (transmitters are deactivated in case of thermal shutdown TSD1 (TSD1 cluster 5 or 6 in cluster mode) Corresponding Failure Bits in Status Registers are set FS Bit (Global Status Byte) is set LS1_FSO and LS2_FSO will be turned on Charge pump is switched off |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |