67 / 118 page ![]() A-1 T1000 Series UPS 5.6-6kVA Installation and Operation Manual – 91074-005 Appendix A: Specifications A.1 T1000 POWER MODULE - 6kVA NOTE: Except for size, weight, and Part Number, the Rackmount and Tower specifications are the same. T1000 6 KVA SPECIFICATIONS - POWER MODULE Parameter Value GENERAL Model No. Tower Tower with Line Cord Rackmount Rackmount with Line Cord T1P0A6000GXG T1P0A6000GXGL1 T1P0A6000GXGR3 T1P0A6000GXGR3L1 Capacity Output 6 kVA Topology True Online, Double conversion, IGBT Power Factor Correction Input INPUT Voltage (V) Single Phase - 208/240 Vin +10% to -15% (L to L)* (Adjustable to +10/-10%, or +15/-20%; set on front panel) (*NOTE: Down to Vin -30% @ 70% Load) Current (Nominal) (A) 25 A @ 240 V (30 A @ 208 V) Current (Max) @ 208 V (A) 32 A Current (Max) @ 240 V (A) 25 A (32 A @ 85% of 240 V) Current (Min.) No-Load @ 240 V (A) 8 A (Typical) Current, Peak Inrush (A) 20 A Peak (Typical) Current Limit (%) 125% Current THD (%) < 5% Frequency (Hz) [and range] 45-65 Hz auto sensing ± 3 Hz Input Power Factor (PF) @ full load Greater than 0.97 Startup Delay (sec) Default: 0 sec (Range: 0 – 800 sec in 1 sec increments) Ground leakage (max.) (mA) 5 mA (UPS only) Internal AC Input Breaker Rating 50 A, 240 V Surge Protection (kA or Category) MOV 250 Joules on Input BYPASS Voltage (V) (selectable) Set by display panel : +10/-15% of nominal (default); +10/-10% of nominal +15/-20% of nominal NOTE: The Display software cannot make floating point (decimal) calculations. There may be differences between the nominal and calculated BYPOV and BYPUV. Example: BYPOV set to 115%, at 208V that should be 239.2V. The decimal value .2 will be truncated (cut off) and the value 239V will be sent to the control board. This will be read back to the display as 114% (114.9% truncates to 114%). Bypass Overload @ 125% Load (min) 10 min. Bypass Overload @ 1000% Load 1 cycle Bypass Disable Automatic (when Input and Output Voltage/Frequency are set to differ- ent values) Automatic Retransfer (Max load % for Retransfer) 4 ms (1/4 cycle) at <105% Max Load |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |