76 / 151 page ![]() NXP Semiconductors FS2400 Fail-safe system basis chip with SMPS and LDO, CAN FD transceiver ABIST can be launched for all the voltage monitoring channels at the same time (via LAUNCH_ABIST bit), or individually (via ABIST_Vxxxx individual bits). An individual diagnostic bit is available for each channel once the ABIST is done (ABIST_DONE = 1). A CLEAR_ABIST bit is available to clear the diagnostic flags before launching the next ABIST. The flags have no impact on the safety pins. If one of the concerned monitored voltage is out of range (OV or UV), the ABIST on demand command is ignored. While the ABIST is running, the other monitoring functions are kept available. TA = −40 °C to 115 °C, unless otherwise specified. VSUP = 5.5 V to 40 V, unless otherwise specified. All voltages referenced to ground. Symbol Parameter Min Typ Max Unit ABIST TABIST ABIST duration for one monitoring channel - - 20 µs Table 48. ABIST electrical characteristics 19.8 Cyclic CRC check The FS24 provides an 8-bit cyclic CRC check to verify the integrity of the INIT registers (FS_I_xxxx) containing the safety configuration information (configurable in INIT mode only). This mechanism allows for the detection of a misconfiguration from the MCU or a bit flip in the INIT registers. The 8-bit CRC is computed on the result of the concatenation of the following register bits: • FS_I_OVUV_CFG1[15:0] • FS_I_OVUV_CFG2[15:0] • FS_I_ERRMON_LIMP0_CFG[15:0] • FS_I_FSSM_CFG[15:4] • FS_I_WD_CFG[15:7] The calculation to apply on the result of the concatenation is the same as the SPI CRC, using x^8+x^4+x^3+x^2+1 polynomial. The MCU must write the obtained CRC in the FS_CRC register before closing the INIT phase, after the modification of the INIT registers. Once the INIT phase is closed and the device is in Normal mode, the cyclic CRC check is launched automatically each 5 ms (TCRC) (<FTTI). Each 5 ms, the device logic recalculates the CRC and compares it to the value stored in FS_CRC register. If a mismatch is reported, the INIT_CRC_NOK_I bit is set and LIMP0 is asserted depending on its impact configuration (INIT_CRC_LIMP0_IMPACT). TA = –40 °C to 115 °C, unless otherwise specified. VSUP = 5.5 V to 40 V, unless otherwise specified. All voltages referenced to ground. Symbol Parameter Min Typ Max Unit Cyclic CRC check TCRC CRC check timing interval 4.75 5 5.25 ms Table 49. Cyclic CRC check characteristics 19.9 Clock monitoring The 1 MHz clock is monitored for stuck-at faults in Normal mode. In case a stuck-at is detected, the two safety pins RSTB and LIMP0 are asserted. FS2400 All information provided in this document is subject to legal disclaimers. © 2024 NXP B.V. All rights reserved. Product data sheet Rev. 4 — 23 October 2024 Document feedback 76 / 151 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |