| Electronic Components Datasheet Search |
|
MM912F634CV2AP Datasheet(PDF) 72 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MM912F634CV2AP Datasheet(HTML) 72 Page - Freescale Semiconductor, Inc |
|
72 / 335 page ![]() Functional Description and Application Information Wake-up / Cyclic Sense MM912F634 Freescale Semiconductor 72 4.8 Wake-up / Cyclic Sense To wake-up the MM912F634 analog die from Stop or Sleep mode, several wake-up sources are implemented. As described in Section 4.3, “Modes of Operation", a wake-up from Stop mode will result in an interrupt (D2DINT) to the MCU combined with a transition to Normal mode. A wake-up from Sleep mode will result in a transition to Reset mode. In any case, the source of the wake-up can be identified by reading the Wake-up Source Register (WSR). The Wake-up Source Register (WSR) has to be read after a wake-up condition in order to execute a new STOP mode command. Two base clock cycles (fBASE) delay are required between the WSR read and MCR write. In general, there are the following seven main wake-up sources: • Wake-up by a state change of one of the Lx inputs • Wake-up by a state change of one of the Lx inputs during a cyclic sense • Wake-up due to a forced wake-up • Wake-up by the LIN module • Wake-up by D2D interface (Stop mode only) • Wake-up due to internal / external Reset (Stop mode only) • Wake-up due to loss of supply voltage (Sleep mode only) Figure 20. Wake-up Sources 4.8.1 Wake-up Sources 4.8.1.1 Lx - Wake-up (Cyclic Sense Disabled) Any state digital change on a Wake-up Enabled Lx input will issue a wake-up. In order to select and activate a Wake-up Input (Lx), the Wake-up Control Register (WCR) must be configured with appropriate LxWE inputs enabled or disabled before entering low power mode. The Lx - Wake-up may be combined with the Forced Wake-up. Note: Selecting a Lx Input for wake-up will disable a selected analog input once entering low power mode. LIN Bus HS1 HS2 L1 L2 L3 L4 L5 VSUP LIN D2DINT D2DCLK D2D3 D2D2 D2D1 D2D0 Wake Up Module D2D Wake Up LIN Wake Up Lx – Wake Up Cyclic Sense / Forced Wake Up Timer Forced Wake Up Cyclic Wake Up L0 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |